DC voltage range | Regulation 650VDC DCI2 Standard |
Input voltage | 400VAC-650V DCI2 Standard |
Grounding scheme applied on AC part (input) | AC-TN-C-S-System |
Grounding scheme applied on DC part (output) | DC-TN-System with AC-side grounding |
Connection power | 11kW |
Peak power | 22kW |
Galvanic isolation? | no |
Ratio of peak to average consumed power | tbd. |
Percentage of reused braking energy | tbd. |
Easy integration of renewable energies? | Yes |
Power of the connected storage | 11kW |
Energy of the connected storage | 5kJ |
Planning with the guideline is completed? | no |
UL/IEC-conform? | no |
Extension possible? | yes |
Retrofit (brownfield) or greenfield? | greenfield |
Companies/partners involved | KEBA, LENZE, TH-OWL, E-T-A, VAHLE, supported by BMWK / PTJ |
Area | Not public, test area |
Public power distributor involved? | no |
Further savings? | Copper reduction 1pole in the busbar system, reduction of cross section, no reactive power |